PULSEDECK v0.10.3

Isolated Aura virtual-device experiment

Resumed at the user's request on 2026-10-04. The unchanged 0.4.0 probe was rebuilt, tested and reinstalled. SYSTEM activation, SDK enumeration and idle exit passed. After an explicitly authorized LightingService restart, its inventory contains PulseDeck and the probe recorded four incoming raw samples, last word 0xFF000000. A separately authorized ArmouryCrateService restart refreshed its inventory: an eighth EXTERNAL_GENERAL entry exists but has empty display name, Type=0 and StatusReady=0. The probe then received ten total samples, last word 0xFF00FFFF, compatible with the user's yellow LEDs under ABGR packing. Channel order and static transitions were then checked with user-applied red (0xFF0000FF), blue (0xFFFF0000) and restored yellow (0xFF00FFFF). The observed packing is 0xAABBGGRR; the high byte's meaning remains unverified. The user confirms a visible "Dispositivi esterni" tile. Color cycle and the agent's physical panel rendering were subsequently verified; full Windows reboot persistence has not yet been checked with this version. The probe's unchanged colorVerified=false label remains conservative runtime metadata; the dated external observations are recorded in validation.

Previously retired from the development PC on 2026-09-17 at the user's request. The user abandoned the virtual Aura-device experiment after repeated missing-tile results. Own class/category registration and installed folder were removed; REGDB_E_CLASSNOTREG and no remaining probe process were verified. ASUS services and PulseDeck were left running. Sources and private runtime backup are preserved. The older installed-state descriptions below are historical/reproduction notes; the current opt-in provider and receiver contract are described next.

The development probe executable hosts the installed ASUS SDK and our minimal HAL for isolated metadata tests. The separate installed destination does not load the ASUS SDK. It receives calls from LightingService and never controls other devices. No vendor binaries, logs or proprietary inspection output belong in Git.

Agent integration (receiver 0.5.0)

The receiver remains an optional, separately installed experimental component. Build it with the command below and install with Manage-InstalledProbe.ps1 in an elevated Windows PowerShell. It is not silently installed by the agent build. After an installation/update, discovery required a LightingService reload followed by an ArmouryCrateService reload on the tested PC. These operations interrupt ASUS services and are not performed automatically by the installer or agent.

Select Dispositivi esterni in Aura Sync, then enable Segui Aura Sync under PulseDeck's Configurazione → Display e musica and save. The manual accent is retained as fallback. Existing configurations default to manual mode. The optional provider reads only the installed SYSTEM destination's report; it never invokes COM/SDK setters or takes lighting ownership. Run the agent through its elevated interactive-user task so it can read the SYSTEM profile. The receiver's SYSTEM COM identity does not change the agent's interactive-user startup requirement.

Protocol version 1 adds a monotonic heartbeatTick, updated at least once per second even for static colors. The agent requires a recent heartbeat and wall-clock timestamp, a live session-0 host with the expected executable path/start time, and a nonzero sample count with the supported incoming envelope. Reports from 0.4.0 are incompatible rather than silently treated as live data. Stops, stale or malformed reports and inaccessible files produce an explicit unavailable state. Static samples may be old while the host heartbeat remains fresh. Availability does not independently prove that the user still selected the device in Aura Sync.

The default build still advertises one LED. An experimental 16-zone horizontal build has been observed receiving 16 distinct simultaneous colors from the live LightingService with Rainbow, across 60 half-second observations on 2026-10-04. The receiver accepts only a complete, bounded UI4 array matching its declared LED count. Build the multizone variant explicitly:

AURA_PROBE_LED_COUNT=16 ./tools/aura-probe/build.sh artifacts/aura-multizone

Counts 1–64 are bounded by the build and decoder; only 1 and 16 have been checked against the installed SDK. Multizone reports use protocol version 2 with ledCount, rawCount and ordered rawWords; version 1 remains readable by the agent. An older agent rejects version 2 and uses its manual fallback, so update the agent as well. rawWord remains the first element for diagnostics, not an average of the zones. The SDK metadata check verifies both the declared width and returned light count.

The renderer reads the latest color, at most twice per second, sharing the same rendering path for PNG preview and the panel. It keeps raw colors on decorations and lightens dark text colors on the dark panel. No additional frame queue is used. The renderer stretches the received color sequence across the PULSEDECK wordmark, active lyric line and music progress bar. Spatial interpolation smooths the colors; only incoming frames move the effect. Sensor bars and rings use one raw color each, selected by their horizontal position. Other accent text uses its local zone with readability adjustment; neutral/status text retains its own color. The ASUS device interface documentation describes ordered lights and matrix dimensions; actual passive reception above was verified separately on this PC. The API exposes status/color/colors/sample time/count through DeckState.aura and the configuration persists auraEnabled; native raw diagnostics remain private.

Build and run

Build in WSL with an i686 MinGW-w64 C compiler:

./tools/aura-probe/build.sh
# Override the compiler path when it is not on PATH:
AURA_PROBE_CC=/path/to/i686-w64-mingw32-gcc ./tools/aura-probe/build.sh /path/to/output

The default output is artifacts/aura-probe. Copy the output directory to Windows, then run in a normal Windows PowerShell session (administrator rights not needed):

./Test-HalDiscovery.ps1
./Test-HalDiscovery.ps1 -EmptyDevices
./Test-HalDiscovery.ps1 -CheckContracts
./Test-HalDiscovery.ps1 -SeparateProcess
./Test-HalDiscovery.ps1 -TestTransport
./Read-ServiceCapabilities.ps1
./Test-ComIsolation.ps1 -WithSdk
./Test-ComIsolation.ps1 -WithSdk -TerminateServer

Only the development build needs MinGW; running the probe needs the locally installed, registered x86 ASUS SDK. The executable uses Windows system libraries, without a .NET or MinGW runtime installation. It is not included in the agent build.

Isolation and assertions

PowerShell launches a disposable native process with a 20-second limit. The child registers the COM factory only inside its own process, temporarily redirects HKCR reads to a private HKCU\Software\PulseDeck\AuraProbe\<random-id> tree, and asks EumerateHalInfo to discover it. The normal registry view is restored before activation. Exactly one entry with our GUID must be present before CreateHal.

By default the SDK enumerates the HAL three times. Each pass must return exactly one device named PulseDeck Virtual Probe, width/height 1x1 and one virtual LED. Read-only effect getters must report exactly one Static descriptor, ID 1, with synchronization disabled (staticEffectDescriptorVerified=true). -EmptyDevices exercises the zero-device case and verifies that no capabilities are requested. Factory/enumeration/capability counters are checked and returned as JSON; any failed assertion or HRESULT makes the child exit nonzero.

No physical HAL, SwitchMode, Apply, LED setter or service control is invoked. The virtual HAL advertises only Static. Its incoming effect callback can forward one raw word for ID 1 as an unverified sample to the receiver, but the test never calls it and requires zero effect/synchronization requests. Synchronization remains E_NOTIMPL. No PC RGB values are sampled. Synthetic transport patterns are generated only by the explicit -TestTransport mode and are labeled synthetic-test.

The parent waits for process exit and removes the private tree on success, failure or timeout. No system-wide COM registration, startup task or ASUS setting is changed. The native executable also refuses scratch paths outside its exact private prefix.

Windows results, SDK 3.07.05.0 — 2026-09-17

Receiver process and reference ownership

-CheckContracts checks our factory/HAL/device ownership directly, without loading ASUS code: 100 iterations exercise both pointer-array and SAFEARRAY return paths, release BSTRs/interfaces/arrays, and assert all root reference counts return to one. This passed. With the SDK, 30 device enumerations left counters 32/31/1 instead of 5/4/1 after three. The excess is specific to the SDK integration path; its exact ownership contract remains unresolved. Do not compensate with arbitrary Release calls or keep that enumeration loop alive indefinitely.

-SeparateProcess starts a receiver child using an inherited, anonymous shared memory mapping and events. The HAL and SDK remain together in the original native host. The receiver does not load ASUS code, enumerate devices or access hardware. Only an explicit handle list is inherited. A job object terminates the receiver when the host exits or crashes; the child is assigned while suspended, before it can execute. An independent 15-second deadline also bounds the receiver lifetime. Normal stop waits for exit before closing its mapping/events.

The IPC buffer stores only the latest sample. Publication does not wait for the consumer; sequence/version checks protect snapshots. -TestTransport sends two opaque test patterns through this transport, verifies their acknowledgements and exact contents, then runs the ordinary SDK discovery checks. This passed with syntheticSamples=2, unverifiedCallbacks=0, colorSource=synthetic-test. The ordinary receiver mode produces hasColorSample=false, colorSource=unavailable.

The receiving HAL callback is wired but has not been exercised by Aura. It accepts only one packed word, forwards it as unverified, and never writes to hardware. The Static descriptor is verified through SDK getters, but packed-color semantics and live delivery remain unverified. Other effect IDs are rejected with E_NOTIMPL. No real Aura color was received. Direct COM interface marshaling between the two experimental processes failed (empty enumeration and a stack-overflow in an adapter experiment); private IPC was selected instead of relying on those vendor proxy contracts. No such experiments ran inside LightingService.

For lifecycle diagnostics, -ObserveSeconds 10 keeps the separate-process test alive briefly. Running it with -TimeoutSeconds 3 intentionally fails. On Windows, both native processes were observed before that timeout; afterwards neither process nor scratch registry key remained. This is a supervisor test, not a successful discovery run. -CheckContracts cannot be combined with the receiver/discovery options.

Next: establish isolated live HAL discovery and the packed-color contract before any physical color comparison. There are no persistent installation commands for LightingService; the optional SYSTEM test below can publish a temporary category entry. No persistent receiver or agent provider has been installed.

The installed GmAcc HAL's virtual branch uses loopback 11000, already owned by Aura Wallpaper, and precedes the wallpaper branch. Its global settings remain unchanged; it is not a verified independent PulseDeck destination.

Read capabilities from the running service

Read-ServiceCapabilities.ps1 requires LightingService to be running and launches a separate native process with a 20-second deadline. It activates the registered ServiceMediator COM local server and calls only get_QueryAllDeviceCap, then checks that the service PID is unchanged. It validates the returned XML and saves it under %LOCALAPPDATA%\PulseDeck\aura-investigation using a unique filename. Only the path, PID and presence of our probe name are printed; the full inventory can contain hardware identifiers and must stay outside Git. No SDK HAL discovery, system registration, refresh request, profile change or LED setter occurs in this mode.

On this PC, the call succeeded with LightingService PID 6840 unchanged. Its response contains Aura Wallpaper locations and no PulseDeck entry. These are capabilities, not live colors or proof that every listed location represents connected hardware. Static inspection of the installed service's manual refresh path shows teardown of effect executors; that path was not invoked. The inspected signature check in DoEnumerateHalInfo targets the SDK DLL, so it does not establish that unsigned HALs are rejected. The process-local factory and private IPC alone do not expose our HAL to LightingService; the newer SYSTEM test below checks cross-session activation and temporary category publication separately from this read-only capability query.

Native COM server in another process

Test-ComIsolation.ps1 starts our native STA server and a direct native client. With -WithSdk, it also runs the existing SDK metadata checks using that external server (externalComHal=true). Only the client uses a private discovery category; the server registers a running class using CLSCTX_LOCAL_SERVER, without Classes or ASUS registry entries. The class is usable by another process in the same user session while the server runs. This is not a LightingService installation.

Direct Enumerate2/GetCapability worked initially, but the SDK path crashed at AuraSdk_x86.dll+0x16b92 because it requires IAacLedDeviceOpt2 from the returned SAFEARRAY. Added the actual inherited Opt/Device2/Opt2 vtable slots and interface identities, rather than returning a base-only vtable under a different IID. Direct and SDK metadata checks now pass. All three additional incoming effect methods return E_NOTIMPL and increment the request counter; no such method is called in these tests. Static metadata recognition does not imply working remote colors.

The server pumps STA messages, waits for stop or supervisor exit and has a 15-second deadline. The supervisor bounds each client, stops its server in finally, and checks that CoGetClassObject subsequently returns REGDB_E_CLASSNOTREG. -TerminateServer deliberately kills only our server after successful checks and verifies the same registration cleanup. Both normal and forced-exit paths passed. -ObserveSeconds 10 permits independent lifecycle observation; terminating that PowerShell supervisor also caused its observed server to exit within three seconds, with the class absent afterwards. The external observer could not retrieve a numeric server exit code, so this last check verifies process/registration cleanup only.

Normal -WithSdk server totals: two activations, seven Enumerate2 calls, four capability reads and zero effect/synchronization requests. The SDK client's local HAL counters must remain zero. Its local reference roots of 1/1/1 do not measure remote references or resolve the previously observed SDK lifetime issue.

LightingService runs as LocalSystem. The next test now verifies activation across that boundary, but real service discovery, color payloads and continuous lifetime remain unverified. That temporary workflow installs no persistent server or agent provider. For the subsequent on-demand installation, see below.

Microsoft reference: running EXE class registration and revocation.

SYSTEM client and optional temporary Aura publication

Run these sequentially from a normal Windows PowerShell session. Each command requests UAC elevation for a short-lived helper; the native COM server continues under the signed-in user's token. No passwords or credentials are supplied.

# Diagnostic baseline: expected class-not-registered from the SYSTEM client.
./Test-SystemComIsolation.ps1
# Temporary identity mapping, direct and private-category SDK checks.
./Test-SystemComIsolation.ps1 -InteractiveIdentity -WithSdk
# Publish our HAL category only after those checks succeed; observe, then remove it.
./Test-SystemComIsolation.ps1 -InteractiveIdentity -WithSdk -ObserveAuraSeconds 30

The helper creates a unique PulseDeck-AuraProbe-<run-id> scheduled task to run our native client as SYSTEM in session 0. It never changes the existing PulseDeck task. -InteractiveIdentity temporarily creates only the probe CLSID's AppID mapping and our AppID's RunAs=Interactive User value under machine Classes. Existing keys cause an abort; no replacement occurs. No LocalServer32 autostart entry, global COM ACL, ASUS setting, SDK control token or service restart is needed.

With -ObserveAuraSeconds (1–60), successful direct and SDK checks are prerequisites for publishing one entry for our CLSID in the SDK third-party HAL category. The helper reads LightingService capabilities every few seconds; it never calls refresh, engine/profile methods or LED setters. Cleanup removes its category, CLSID, AppID and unique task, then verifies absence. Output distinguishes SYSTEM test results from actual service observations. Full audit JSON and capability XML remain under the interactive user's LOCALAPPDATA/PulseDeck/aura-investigation, explicitly passed to the SYSTEM phase; nothing is stored alongside source files. Before announcing publication, a bounded native --registered-hal-info read also requires exactly one probe GUID in the SDK's real registry inventory. It never calls CreateHal on those entries, so no vendor hardware module is activated by this check.

The native server supports a validated 1–120-second lifetime (default 15). This workflow uses 120, watches supervisor exit and normally shuts down sooner. Its added effect methods still return E_NOTIMPL: advertising Static metadata does not yet make it a usable live color receiver.

Windows results:

The absence of activation does not establish an ASUS signature rejection. The next question is when/how the running service refreshes its HAL inventory under the user's normal Armoury Crate workflow. Do not turn the existing read-only query into an unverified service refresh call.

Microsoft references: RunAs identity, CLSID/AppID mapping.

Inspect contracts without activating COM

./Inspect-TypeLibrary.ps1 -Path 'C:\Program Files\ASUS\AuraSDK\AuraSdk_x86.dll'
./Inspect-TypeLibrary.ps1 -Path 'C:\Program Files\ASUS\ASUS_Aac_DRAM\Aac3572DramHal.tlb' -TypePattern '^IAacLedDeviceHal'

This reads metadata using LoadTypeLibEx(REGKIND_NONE) and never registers the library. Store results under %LOCALAPPDATA%\PulseDeck, not Git. Interface GUIDs and method signatures describe interoperability contracts; the C implementation and virtual-device capability description are our own.

Microsoft references: process-local registry redirection, COM registration, type-library loading.

Reversible on-demand installation (experimental)

The development PC now has an experimental registration for a separate PulseDeck.AuraHal.exe under C:\Program Files\PulseDeck Aura Probe. This does not establish an Armoury Crate tile or usable RGB receiver. Effect callbacks remain unsupported, and no PulseDeck agent provider is enabled.

Run from the built native-probe directory in elevated Windows PowerShell:

./Manage-InstalledProbe.ps1 -Action Install
./Manage-InstalledProbe.ps1 -Action Status
./Manage-InstalledProbe.ps1 -Action Remove

The installed copy of Manage-InstalledProbe.ps1 also supports Status/Remove. Install refuses an existing directory or any of our class/AppID/category keys. It copies only our executables/scripts into an admin-owned folder, applies explicit read/execute-only access for Users and records ownership plus SHA-256 hashes. It registers the exact probe CLSID's x86 LocalServer32 path, fully quoted, plus ServerExecutable. No AppID/RunAs, permanent scheduled task or Windows service is created. COM launches the HAL as its caller, including SYSTEM/session 0, rather than requiring a server already running in an interactive login.

Before category publication, a unique bounded SYSTEM task verifies automatic startup, direct COM metadata, three private-category SDK enumerations and idle exit. The server retains no ASUS SDK and no hardware ownership. It pumps its STA, honors COM references/locks, and exits after 15 idle seconds. It suspends class activation before final shutdown. The task is removed; failures roll back owned registration/files. If removal cannot observe our server exit within ten seconds, files are retained for retry instead of forcibly terminating another process or removing locked binaries. Unexpected files in the directory are preserved. Abrupt termination/power loss of the installer is not a tested transactional rollback guarantee.

Reports contain metadata/counters only, one latest file per account/session: %LOCALAPPDATA%\PulseDeck\aura-installed-probe\session-<id>.json. The x86 SYSTEM process writes under C:\Windows\SysWOW64\config\systemprofile\AppData\Local\PulseDeck. Status reads available reports without activating the HAL; run elevated to read SYSTEM's report. Installation audit results remain in the installer's LOCALAPPDATA under PulseDeck\aura-investigation\installed-runs. Preserve the audit as the baseline: two activations/seven enumerations/four capability reads came from our SYSTEM test, not ASUS. Report timestamps and PIDs distinguish later starts.

After a user-initiated reboot, read Status before running any direct/SDK activation test, then read existing service capabilities and inspect Aura Sync. No reboot or ASUS service restart is performed by these scripts. Detection after reboot and physical RGB correspondence remain unverified. Do not invoke the old temporary COM, SYSTEM identity or class-absence tests while installed: they share the same CLSID.

Windows validation: SYSTEM automatic launch and idle exit passed; attempting a second Install was refused; Remove left REGDB_E_CLASSNOTREG and no category/class keys; reinstall passed the same SYSTEM checks. No temporary tasks remained and ASUS service PIDs were unchanged. The service still did not report PulseDeck.

Microsoft references: LocalServer32 command registration, launching-user identity, class suspension.

Subsequent user reboot result

The user still sees no PulseDeck tile. Before any activation self-test, elevated Status found a new session-0 HAL process and a post-boot report with one activation, two enumerations, one capability read and two effect callbacks. Thus startup now loads the component and reaches its incoming methods; the caller PID and specific callback payloads are not recorded yet. The existing service capability getter still omits the probe name. E_NOTIMPL callbacks may matter to initialization, but that is an unverified hypothesis. No real RGB sample has been received/validated. See the dated validation record before interpreting the earlier negative results.

Detailed service inventory and device classification

Use Read-ServiceCapabilities.ps1 -Query Devices for the separate, bounded, read-only IServiceMediator.get_QueryAllDevice method (DISPID 63, no arguments, BSTR return verified in the installed type library). The default Capabilities mode is unchanged. The detailed response identifies our manufacturer/model even where our HAL Name is absent. ContainsProbeName remains a literal string check only; ProbeIdentityCount and ProbeDevices report the matched inventory entries.

On this PC the old type-0 prototype is present as Type/LightingName All, model Isolated test destination, manufacturer PulseDeck, one LED, among 15 entries. This supersedes the inference that a missing Name meant a missing device. Static inspection of LightingService 3.10.12 maps 0x64000 to EXTERNAL_GENERAL. The updated prototype uses that type and PulseDeck Virtual Probe as both name and model; its SDK test now asserts Type == 409600. No existing device category is impersonated. Static's synchronizable flag stays zero; tile eligibility is not established by changing it. The running service can retain its old inventory until a new scan.

Installed JSON additionally records deviceType and the last incoming call shape: lastEffectMethod 1=SetEffect, 2=SetEffectOptSpeed, 3=SetEffect2, 4=SetEffectOptSpeed2; lastEffectId/count/variant are raw metadata. Variant is zero for pointer-based methods, otherwise the unmodified VARTYPE including flags. These are incoming methods on our own destination, never outgoing calls by our probe. No color buffer is decoded by the added diagnostics. The installed host still returns E_NOTIMPL and cannot claim real colors or successful effect handling.

Validated incoming envelope (probe 0.4.0)

The service later acquired EXTERNAL_GENERAL/PulseDeck metadata without another boot, while the user still saw no tile. Vendor SDK logs identify LightingService PID 6456 as the enumerating process; the service reported Apply Failed for our virtual model. The latest incoming call shape was SetEffect2, ID 0, count 1, VARTYPE 8211.

The own callback now accepts exactly this envelope, copies the one raw ULONG and returns S_OK. It does not assume byte order or that this is the current PC color. All other effect variants/IDs remain unsupported. Latest report fields rawSamples, rawWord, rawSampleTick and colorVerified=false distinguish unverified incoming data; zero rawSamples means no data, regardless of rawWord's default zero. No frame queue.

PulseDeck.AuraProbe.exe --check-incoming runs synthetic decoder fixtures without calling any HAL/SDK effect method. Fifteen checks cover null inputs, wrong count, BYREF, empty/multiple elements, wrong rank/element type/size, plus a valid nonzero lower bound. Own COM/SDK metadata regressions must still report zero effect calls. Live delivery after host replacement, tile visibility and physical color matching remain separate checks; a successful decoder test cannot establish them.